Hichrom C8 and C18 色谱柱
- Capillary to preparative scale dimensions
- ISO 9001:2008 (Quality) and ISO 14001:2004 (Environmental) standards
- Every column exceeds stringent quality test criteria
- Exceptional reproducibility and efficiency
- See also Partisil/Partisphere and Ultrasphere sections
Hichrom has been firmly established in the field of chromatography for over 30 years, specialising in the development, manufacture and supply of high quality HPLC products, both in the UK and throughout the entire world. During this time Hichrom has built up a strong reputation amongst chromatographers for technical expertise, speed of delivery and competitive pricing. Hichrom is accredited to both ISO 9001:2008 (Quality) and ISO 14001:2004 (Environmental) standards. Every Hichrom manufactured column exceeds stringent quality criteria and all columns are supplied with documentation enabling a complete audit trail from the time of manufacture to the point of use. In addition to the following range of Hichrom branded columns (pages 132-140) Hichrom offer a wide range of HPLC columns packed with any commercially available silica (see page 63), an OEM manufacturing and custom bonding service and also manufacture the Partisil and Partisphere (see pages 189-193) and the Ultrasphere (see pages 258-259 ) brands.
Hichrom C8 and C18
Hichrom’s C8 and C18 columns offer high performance in order to tackle the most challenging reversed-phase applications. The use of ultra pure silica, advanced bonding technology, superior column specification and comprehensive batch validation all contribute to the columns’ excellent reproducibility.
Hichrom Phases
Phase | Functional Group | Endcapped | Particle Size (μm) | Pore Size (Å) | Surface Area (m2/g) | Carbon Load (%) |
C18 | Octadecyl | Yes | 3.5, 5 | 150 | 250 | 15 |
C8 | Octyl | Yes | 3.5, 5 | 150 | 250 | 8 |
Excellent Batch Reproducibility
Combining ultra pure silica with advanced bonding technology results in a densely bonded silica that is both highly robust and highly reproducible. Unpredictable interactions between residual silanol sites on the silica surface and the analyte are effectively eliminated. Comprehensive batch validation ensures absolute batch to batch reproducibility is maintained with acidic, basic and neutral molecules. Figures 1 and 2 show two of the tests used during the validation of Hichrom C8 and C18 phases.
Test Conditions | Test Components | Test Conditions | Test Components | ||
Column: Hichrom 5 C18 (250 x 4.6 mm) | 1. Uracil | Column: Hichrom 5 C18 (250 x 4.6 mm) | 1. Norephedrine | ||
Eluent: CH3CN – 0.05M KH2PO4, pH 3.2 (60:40) | 2. | Pyridine | Eluent: CH3OH – 0.025M KH2PO4, pH 6.0 (80:20) | 2. Nortriptyline | |
Flow rate: 1 ml/min | 3. | Phenol | Flow rate: 1 ml/min | 3. Toluene | |
Temperature: Ambient | 3 | 4. | Dimethyl phthalate | Temperature: Ambient | 4. Imipramine |
5. | N,N-Dimethylaniline | 5. Amitriptyline | |||
3 | |||||
6. | 4-Butylbenzoic acid | ||||
7. Toluene | 2 | ||||
2 | 5 | 7 | |||
1 | 4 | ||||
1 | 5 | ||||
4 | |||||
6 |
0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 Mins | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | Mins |
Figure 1. Validation test – Selectivity with acidic, basic and neutral molecules | Figure 2. Validation test – Tricyclic antidepressants |
Every Hichrom C8 and C18 column is individually manufactured and meticulously tested in the Hichrom laboratory. Efficiency measurements and two peak asymmetry calculations are recorded for each component of the quality control test mixture. Samples of the quality control test mixture are available on request. Only columns exceeding the most stringent efficiency and peak shape specifications are approved for sale.
All Hichrom C8 and C18 columns are supplied with a Test Chromatogram and Batch Validation Certificate. Information regarding column care and use is displayed on the reverse of the Test Chromatogram.
e research and development.
Bonding Stability
Combining a unique dense bonding process (inhibiting ligand cleavage at low pH) with a revolutionary capping process (shielding the silica from dissolution at high pH) enables Hichrom C8 and C18 columns to offer exceptional stability across an extended pH range. Figure 5 demonstrates the acid robustness of a Hichrom 5 C18 column.
Column Robustness
A stable packed silica bed is critical to the long term performance of the column. Hichrom C8 and C18 columns are packed to extremely high efficiencies with excellent peak asymmetries, ensuring that high performance is maintained throughout the column’s lifetime. Figure 6 shows that the performance of both Hichrom 3.5μm C18 and Hichrom 5μm C18 columns remains unaffected after extended use.
C18 column dimensions, to further extend column lifetime by preventing irreversible adsorption and frit blockage at the top of the column. As shown in Figure 7, a fingertight column coupler (HI-081) is used to connect the guard holder (HI-161) to a Hichrom 5 C18 column. Further information on the guard cartridge range is listed on pages 24 and 25.
Hichrom
Ordering Information – Hichrom C8 and C18
Microbore (1.0mm i.d.) Columns
Hichrom Phase | Column Dimensions1 (mm) | Guard Cartridges | 2 | |||
50 x 1.0 | 100 x 1.0 | 150 x 1.0 | 250 x 1.0 | (For 1.0mm i.d. Columns) | ||
3.5μm | – | (5/pk)3 | ||||
C8 | HI-3.5C8-50M | HI-3.5C8-100M | HI-3.5C8-150M | – | HI-3.5C8-10CE5 | |
C18 | HI-3.5C18-50M | HI-3.5C18-100M | HI-3.5C18-150M | – | HI-3.5C18-10CE5 | |
5μm | (5/pk)3 | |||||
C8 | HI-5C8-50M | HI-5C8-100M | HI-5C8-150M | HI-5C8-250M | HI-5C8-10CE5 | |
C18 | HI-5C18-50M | HI-5C18-100M | HI-5C18-150M | HI-5C18-250M | HI-5C18-10CE5 | |
Microbore (2.1mm i.d.) Columns
Hichrom Phase | Column Dimensions1 (mm) | Guard Cartridges | 2 | |||
50 x 2.1 | 100 x 2.1 | 150 x 2.1 | 250 x 2.1 | (For 2.1mm i.d. Columns) | ||
3.5μm | – | (5/pk)3 | ||||
C8 | HI-3.5C8-50AM | HI-3.5C8-100AM | HI-3.5C8-150AM | – | HI-3.5C8-10CM5 | |
C18 | HI-3.5C18-50AM | HI-3.5C18-100AM | HI-3.5C18-150AM | – | HI-3.5C18-10CM5 | |
5μm | (5/pk)3 | |||||
C8 | HI-5C8-50AM | HI-5C8-100AM | HI-5C8-150AM | HI-5C8-250AM | HI-5C8-10CM5 | |
C18 | HI-5C18-50AM | HI-5C18-100AM | HI-5C18-150AM | HI-5C18-250AM | HI-5C18-10CM5 | |
Medium Bore (3.2mm i.d.) Columns
Hichrom Phase | Column Dimensions1 (mm) | Guard Cartridges | 2 | |||
50 x 3.2 | 100 x 3.2 | 150 x 3.2 | 250 x 3.2 | (For 3.2mm i.d. Columns) | ||
3.5μm | – | (5/pk)3 | ||||
C8 | HI-3.5C8-50AS | HI-3.5C8-100AS | HI-3.5C8-150AS | – | HI-3.5C8-10C5 | |
C18 | HI-3.5C18-50AS | HI-3.5C18-100AS | HI-3.5C18-150AS | – | HI-3.5C18-10C5 | |
5μm | (5/pk)3 | |||||
C8 | HI-5C8-50AS | HI-5C8-100AS | HI-5C8-150AS | HI-5C8-250AS | HI-5C8-10C5 | |
C18 | HI-5C18-50AS | HI-5C18-100AS | HI-5C18-150AS | HI-5C18-250AS | HI-5C18-10C5 | |
Analytical (4.0mm i.d.) Columns
Hichrom Phase | Column Dimensions1 (mm) | Guard Cartridges | 2 | ||||
50 x 4.0 | 100 x 4.0 | 150 x 4.0 | 250 x 4.0 | (For 4.0mm i.d. Columns) | |||
3.5μm | – | (5/pk)3 | |||||
C8 | HI-3.5C8-50AF | HI-3.5C8-100AF | HI-3.5C8-150AF | – | HI-3.5C8-10C5 | ||
C18 | HI-3.5C18-50AF | HI-3.5C18-100AF | HI-3.5C18-150AF | – | HI-3.5C18-10C5 | ||
5μm | (5/pk)3 | ||||||
C8 | HI-5C8-50AF | HI-5C8-100AF | HI-5C8-150AF | HI-5C8-250AF | HI-5C8-10C5 | ||
C18 | HI-5C18-50AF | HI-5C18-100AF | HI-5C18-150AF | HI-5C18-250AF | HI-5C18-10C5 | ||
Analytical (4.6mm i.d.) Columns
Hichrom Phase | Column Dimensions1 (mm) | Guard Cartridges | 2 | ||||
50 x 4.6 | 100 x 4.6 | 150 x 4.6 | 250 x 4.6 | (For 4.6mm i.d. Columns) | |||
3.5μm | – | (5/pk)3 | |||||
C8 | HI-3.5C8-50A | HI-3.5C8-100A | HI-3.5C8-150A | – | HI-3.5C8-10C5 | ||
C18 | HI-3.5C18-50A | HI-3.5C18-100A | HI-3.5C18-150A | – | HI-3.5C18-10C5 | ||
5μm | (5/pk)3 | ||||||
C8 | HI-5C8-50A | HI-5C8-100A | HI-5C8-150A | HI-5C8-250A | HI-5C8-10C5 | ||
C18 | HI-5C18-50A | HI-5C18-100A | HI-5C18-150A | HI-5C18-250A | HI-5C18-10C5 | ||
Semi-Preparative (7.75mm i.d.) Columns
Hichrom Phase | Column Dimensions1 (mm) | Guard Cartridges | 4 | |||||||
50 x 7.75 | 100 x 7.75 | 150 x 7.75 | 250 x 7.75 | (For 7.75mm i.d. Columns) | ||||||
5μm | (3/pk) | |||||||||
C8 | HI-5C8-50SP | HI-5C8-100SP | HI-5C8-150SP | HI-5C8-250SP | HI-5C8-10CP3 | |||||
C18 | HI-5C18-50SP | HI-5C18-100SP | HI-5C18-150SP | HI-5C18-250SP | HI-5C18-10CP3 | |||||
Other column dimensions available – please enquire | 3 | Starter kits | available – see p. 25 | |||||||
Use with free-standing holder HI-161 | and column coupler HI-081 | – see p. 24 | 4 | Use with free-standing holder HI-150 | and column coupler HI-081 | – see p. 24 |
Hichrom
Ordering Information – Hichrom C8 and C18 (continued)
Semi-Preparative (10.0mm i.d.) Columns
Hichrom Phase | Column Dimensions1 (mm) | Guard Cartridges2 | |||
50 x 10.0 | 100 x 10.0 | 150 x 10.0 | 250 x 10.0 | (For 10.0mm i.d. Columns) | |
5μm | (3/pk) | ||||
C8 | HI-5C8-50SP1 | HI-5C8-100SP1 | HI-5C8-150SP1 | HI-5C8-250SP1 | HI-5C8-10CP3 |
C18 | HI-5C18-50SP1 | HI-5C18-100SP1 | HI-5C18-150SP1 | HI-5C18-250SP1 | HI-5C18-10CP3 |
Preparative (21.2mm i.d.) Columns
Hichrom Phase | Column Dimensions1 (mm) | Guard Cartridges | 2 | ||||
50 x 21.2 | 100 x 21.2 | 150 x 21.2 | 250 x 21.2 | (For 21.2mm i.d. Columns) | |||
5μm | (3/pk) | ||||||
C8 | HI-5C8-50P | HI-5C8-100P | HI-5C8-150P | HI-5C8-250P | HI-5C8-10CP3 | ||
C18 | HI-5C18-50P | HI-5C18-100P | HI-5C18-150P | HI-5C18-250P | HI-5C18-10CP3 |
Preparative (30.0mm i.d.) Columns
Hichrom Phase | Column Dimensions1 (mm) | Guard Cartridges | 3 | ||||||
50 x 30.0 | 100 x 30.0 | 150 x 30.0 | 250 x 30.0 | (For 30.0mm i.d. Columns) | |||||
5μm | (1/pk) | ||||||||
C8 | HI-5C8-50P3 | HI-5C8-100P3 | HI-5C8-150P3 | HI-5C8-250P3 | HI-5C8-20CP | ||||
C18 | HI-5C18-50P3 | HI-5C18-100P3 | HI-5C18-150P3 | HI-5C18-250P3 | HI-5C18-20CP | ||||
1 | Other column dimensions available – please enquire | 3 Use with free-standing holder HI-183 | and column coupler HI-083 | ||||||
2 | Use with free-standing holder HI-150 | and column coupler HI-081 |